A NARX Model to Predict Cabin Air Temperature to Ameliorate HVAC Functionality

datacite.relatedItem.firstPage872
datacite.relatedItem.issue4
datacite.relatedItem.relatedIdentifierTypeISSN
datacite.relatedItem.relatedItemIdentifier2624-8921
datacite.relatedItem.relationTypeIsPublishedIn
datacite.relatedItem.titleVehicles
datacite.relatedItem.volume3
dc.contributor.authorSrikanth Kolachalama
dc.contributor.authorHafiz Malik
dc.date.accessioned2025-05-21T03:32:08Z
dc.date.available2025-05-21T03:32:08Z
dc.date.issued2021
dc.identifier.doihttps://doi.org/10.3390/vehicles3040052
dc.identifier.otherjz000163-0052
dc.identifier.urihttps://tustorage.ulb.tu-darmstadt.de/handle/tustorage/33752
dc.publisherMDPI AG
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc530
dc.titleA NARX Model to Predict Cabin Air Temperature to Ameliorate HVAC Functionality